Regarding the position of the basic diameter on NPT taps

【英】困ったときの知恵袋詳細
Cutting Taps Pipe Threads Standard (Screw Threads, Center Holes)How to useSpecification of toolsBasic Knowledge
I am looking at YAMAWA’s general catalog. In the dimensional table for the “ANSI Standard NPT Tap Series,” what does “Projection” refer to?
In the tap standards, unlike JIS, ANSI does not have an item for “ℓg - basic diameter position.”Instead, they list “Projection.”In NPT, the “L1 (thread length at hand-tight engagement)” is specified, and the position of the basic diameter is determined by adding the values of “L1 ring gauge” and “Projection.”